Search productSearch post

Life technology is so close

Pharmaceutical Sciences

HCY Stool Collection Kit Disposable Sampler Microbial Culture Swab Kit

HCY Stool Collection Kit Disposable Sampler Microbial Culture Swab Kit

Introduction of Fecal Collection Kit:

 

Huachenyang Fecal Collection Kit is the newest bacterial transport swab that provides the ability to distinguish aerobic or anaerobic bacteria during collection, transportation, or indoor storage at the temperature required for potassium chloride, magnesium chloride, and calcium chloride ions And to maintain the survival rate, the appropriate buffer can keep the shape of the sample intact to the greatest extent so that it can be fully suspended and dispersed. The use of different reagent formulations and the specificity of compatible swabs allows for greater sample collection, better transport, and storage.

If you need free samples, you can submit an inquiry to us and we will reply immediately

*
*
*

Country

Submitting!
Successfully submitted!
Submission failed!
Email error!
Phone error!

Product Details:

Place of Origin: China
Brand Name: HUACHENYANG
Certification: ISO13485,NMPA,
Model Number: CY-930003T-Cary Blair

HCY Stool Collection Kit Disposable Sampler Microbial Culture Swab Kit

Description

Model: CY-930003T-Cary Blair Brand: HUACHENYANG
Product Name: Sample Collection Kit Packaging Parameters 1: 25 Servings/pack
Packaging Parameters 2: 500 Servings/box Production Place: Shenzhen, China
High Light:

HCY Stool Collection Kit

,

500 servings/box Stool Collection Kit

,

Microbial Culture Swab Kit

 

Fecal Collection Kit

 

HCY Stool Collection Kit Disposable Sampler Microbial Culture Swab Kit

 

Introduction of Fecal Collection Kit:

 

Huachenyang Fecal Collection Kit is the newest bacterial transport swab that provides the ability to distinguish aerobic or anaerobic bacteria during collection, transportation, or indoor storage at the temperature required for potassium chloride, magnesium chloride, and calcium chloride ions And to maintain the survival rate, the appropriate buffer can keep the shape of the sample intact to the greatest extent so that it can be fully suspended and dispersed. The use of different reagent formulations and the specificity of compatible swabs allows for greater sample collection, better transport, and storage.

Advantages of Fecal Collection Kit:

 

The Fecal Collection Kit has excellent sample collection and release capabilities, and can quickly adsorb small samples with high release efficiency. The positive duration of nucleic acid detection of anal swabs is longer than that of oropharyngeal swabs, which can supplement the detection loopholes of oropharyngeal swabs and prevent missed diagnoses. In the past, oral and throat swab tests collected samples through the oral or nasal cavity, which was an uncomfortable experience for the subjects. After sampling, some people will experience nausea, vomiting, nausea, etc., but the Fecal Collection Kit test will not appear in the above situation, but it will test the psychological endurance of the subjects. Anal swab tests last longer and theoretically test samples more accurately

Fecal Collection Kit uses:

 

Fecal Collection Kit is used for sample collection, transportation, storage, etc.

Fecal Collection Kit parameters:

 

The Fecal Collection Kit consists of a swab and a test tube containing a preservation solution. Provided non-sterile.

 

model CY-930003T-Cary Blair
brand HUACHENYANG
product name Sample Collection Kit
Packaging parameters 1 25 servings/pack
Packaging parameters 2 500 servings/box
production place Shenzhen, China

 

Product Instructions:

1. Take out the sampling swab, do not touch other parts or other places (so as not to contaminate the swab).

2. Gently insert the swab 3-5 cm into the anus.

3. Scrape a sufficient number of samples directly with a sampling rod, and the ratio of sample to preservation solution is 0.01-0.25:1.

4. Use the swab in the anus for 4~5 turns and then gently pull out the swab.

5. Put the sampling swab into the test tube containing the preservation solution, and quickly stir about 10 times to elute the sample on the swab. Then push the sampling swab head from the tail and tighten the cap

 

Sample requirements:

 

The collected samples must be fresh and sent for inspection in time. The pathogenic bacteria after collection should be

It should be sent to the laboratory within 48 hours at 2-8 °C. If it cannot be sent to the laboratory within 48 hours, it should be stored at -70 °C or below. The pathogenic bacteria samples should be inoculated and separated as soon as possible after they are sent to the laboratory. After inoculation and separation within 48 hours, they can be stored at 2-8 °C. If it is not inoculated and separated in time, it should be stored at -70°C or below.

 

Precautions:

 

① After the specimen is collected, the disposable sampling swab should be completely inserted into the preservation solution to maximize the retention of the specimen

 

② The collected specimens must be fresh and sent for inspection in time to avoid the death of pathogenic bacteria.

 

③ It is forbidden to use products with damaged packaging and expired expiry date to prevent pollution.

 

Note: This disposable sampler is used for in vitro diagnostic purposes, and cannot be used for internal or external use in humans or animals. If swallowed, it can cause serious incidents; it is irritating to the eyes and skin. If splashed into the eyes accidentally, rinse with water.

 

 

Packing specification:

25 servings/pack

500 servings/box

Expand more!
HCY Stool Collection Kit Disposable Sampler Microbial Culture Swab KitHCY Stool Collection Kit Disposable Sampler Microbial Culture Swab Kit

Click on the inquiry