Search productSearch post

Life technology is so close

Pharmaceutical Sciences

HCY Antigen Detection Kit Supplier 15 Minutes Covid Rapid Detection

HCY Antigen Detection Kit Supplier 15 Minutes Covid Rapid Detection

HCY Antigen Detection Kit Description:

 

HCY Antigen Detection Kit (Lateral Chromatography) is an immunochromatographic method for rapid qualitative detection of SARS-CoV-2.

 

The test is designed to identify SARS-CoV-2 nucleocapsid antigens typically detected in upper respiratory tract samples during the acute phase of infection. A positive result indicates the presence of viral antigens, but the infection status needs to be judged in combination with a medical history and other diagnostic information. Positive results indicate a bacterial infection or association with other viruses, and co-infection cannot be ruled out.

If you need free samples, you can submit an inquiry to us and we will reply immediately

*
*
*

Country

Submitting!
Successfully submitted!
Submission failed!
Email error!
Phone error!

Product Details:

Place of Origin: China
Brand Name: HUACHENYANG
Certification: CE、FDA、ISO

HCY Antigen Detection Kit Supplier 15 Minutes Covid Rapid Detection

Description

Product Name: Covid Test Kit Type: Non Invasive Collection
Brand: HUACHENYANG Accessory 3: Sample Buffer
Place Of Origin: China Packaging: 1 Test/box, 25 Tests/box
High Light:

HCY Antigen Detection Kit

,

Covid Antigen Detection Kit

,

HCY Rapid Detection Kit

 

HCY Antigen Detection Kit Supplier 15 Minutes Covid Rapid Detection​

 

HCY Antigen Detection Kit Supplier 15 Minutes Rapid Detection Kit Wholesale 

 

HCY Antigen Detection Kit Description:

 

HCY Antigen Detection Kit (Lateral Chromatography) is an immunochromatographic method for rapid qualitative detection of SARS-CoV-2.

 

The test is designed to identify SARS-CoV-2 nucleocapsid antigens typically detected in upper respiratory tract samples during the acute phase of infection. A positive result indicates the presence of viral antigens, but the infection status needs to be judged in combination with a medical history and other diagnostic information. Positive results indicate a bacterial infection or association with other viruses, and co-infection cannot be ruled out.

 

Precautions for HCY Antigen Detection Kit:

 

Negative results should be considered speculative, do not exclude SARS-CoV-2 infection, and should not be used as the sole basis for treatment or patient management decisions, including infection control decisions.

Use of HCY Antigen Detection Kit:

 

For patients with suspected symptoms, mild symptoms, or even asymptomatic patients, the HCY Antigen Detection Kit can also be used to detect close contact with infected patients and isolate management personnel.

 

HCY Antigen Detection Kit application:

 

Using human whole blood, serum, or plasma

Rapid Qualitative Differential Test for IgG and IgM Antibodies

Provides clinical results in 2-10 minutes

Visual Interpretation of Results

No special equipment required

 

product name Covid Test Kit
Type Non invasive collection
brand HUACHENYANG
Accessory 3 sample buffer
Place of production China
Packaging 1 test/box, 25 tests/box

 

HCY Antigen Detection Kit Description:

 

Prepare to test:

 

Remove one extraction tube and one COVID-19 Antigen Detection Kit (Lateral Chromatography) from the HCY Antigen Detection Kit foil pouch immediately before testing

 

Label test cartridges and extraction tubes for each sample to be tested. Place the labeled extraction tubes on the rack in the designated area of the workspace. See Figure 1.

 

Nasal swab specimen collection:

 

To collect a nasal swab sample, carefully insert the swab (provided in the kit) into the most visually efficient nostril. Gently rotating, push the swab until it meets resistance at the level of the turbinate (approximately 2.0-2.5 cm or nearly 1 inch into the nostril). Roll the swab around the nasal wall about 5 times and remove it from the nostril.

Sample Preparation:

Unscrew the cap of the sample extraction buffer bottle, squeeze the sample extraction buffer bottle, and add the sample extraction buffer to the extraction tube. (See Figure 2) Immediately after specimen collection, immerse the swab in the sample extraction buffer. (See Figure 3) To allow the extracted sample to fully penetrate the buffer of the swab, rotate the swab against the tube wall repeatedly for 10 seconds, then hold the tube with your fingers (the tube wall is semi-solid) and squeeze and wipe Several times, slowly remove the swab from the tube at the same time. (See Figure 4) The purpose of squeezing the swab against the tube wall is important because it keeps the liquid-containing specimen as much as possible in the tube. After removing the swab and discarding it in the biohazard waste container, tie the nozzle (provided in the kit) to the top of the extraction tube and gently shake the tube to thoroughly mix the liquid inside, see Figure 5.

test program:

1. Please read the instructions carefully before testing.
2. Invert the specimen extraction tube and keep it upright. Squeeze the test tube, and add more than 3 drops of the sample solution (about 70-90 μL) into the test tube through the nozzle of the test tube.
3. Start the timer. Visually read results at 15 minutes. Do not interpret results after 30 minutes.

Expand more!
HCY Antigen Detection Kit Supplier 15 Minutes Covid Rapid DetectionHCY Antigen Detection Kit Supplier 15 Minutes Covid Rapid Detection

Click on the inquiry