Search productSearch post

Life technology is so close

Pharmaceutical Sciences

OEM ODM Fecal Collection Kit Anal Swab Stool Collection Kit

OEM ODM Fecal Collection Kit Anal Swab Stool Collection Kit

Product advantages:

 

With excellent sample collection and release capabilities, it can quickly adsorb small samples with high release efficiency. The duration of positive nucleic acid detection in anal swabs is longer than that in oral and pharyngeal swabs, which can supplement the detection loopholes of oral and pharyngeal swabs to prevent missed diagnosis. In the past oral and throat swab tests, samples were taken through the oral cavity or nasal cavity, which was an uncomfortable experience for the subjects. After sampling, some people would experience nausea, vomiting, nausea, etc., while The anal swab test will not have the above situation, but it will test the psychological endurance of the subjects. Anal swabs have a higher test duration and theoretically more accurately test samples

If you need free samples, you can submit an inquiry to us and we will reply immediately

*
*
*

Country

Submitting!
Successfully submitted!
Submission failed!
Email error!
Phone error!

Product Details:

Place of Origin: China
Brand Name: HUACHENYANG
Certification: ISO13485,NMPA,
Model Number: CY-930003T-Amies

OEM ODM Fecal Collection Kit Anal Swab Stool Collection Kit

Description

Model Number: CY-90003Amies Brand Name: HUACHENYANG
Size: / Instrument: Class I
Validity Period: 12 Months Place Of Origin: Guangdong, China
High Light:

OEM ODM Fecal Collection Kit

,

Anal Swab Fecal Collection Kit

,

Anal Swab Stool Collection Kit

 

OEM ODM Fecal Collection Kit Anal Swab Stool Collection Kit

 

Anal swab stool collection kit nylon flocked swab individually packaged stool swab

 

Product advantages:

 

With excellent sample collection and release capabilities, it can quickly adsorb small samples with high release efficiency. The duration of positive nucleic acid detection in anal swabs is longer than that in oral and pharyngeal swabs, which can supplement the detection loopholes of oral and pharyngeal swabs to prevent missed diagnosis. In the past oral and throat swab tests, samples were taken through the oral cavity or nasal cavity, which was an uncomfortable experience for the subjects. After sampling, some people would experience nausea, vomiting, nausea, etc., while The anal swab test will not have the above situation, but it will test the psychological endurance of the subjects. Anal swabs have a higher test duration and theoretically more accurately test samples

 

Product Usage:

 

For sample collection, transportation and storage, etc.

 

Product parameter:

 

It consists of a swab and a test tube containing a preservation solution. Provided non-sterile.

 

Product Instructions:

1. Take out the sampling swab, do not touch other parts or other places (so as not to contaminate the swab).

2. Gently insert the swab 3-5 cm into the anus.

3. Scrape a sufficient number of samples directly with a sampling rod, and the ratio of sample to preservation solution is 0.01-0.25:1.

4. Use the swab in the anus for 4~5 turns and then gently pull out the swab.

5. Put the sampling swab into the test tube containing the preservation solution, and quickly stir about 10 times to elute the sample on the swab. Then push the sampling swab head from the tail and tighten the cap

 

Sample requirements:

 

The collected samples must be fresh and sent for inspection in time. The pathogenic bacteria after collection should be

It should be sent to the laboratory within 48 hours at 2-8 °C. If it cannot be sent to the laboratory within 48 hours, it should be stored at -70 °C or below. The pathogenic bacteria samples should be inoculated and separated as soon as possible after they are sent to the laboratory. After inoculation and separation within 48 hours, they can be stored at 2-8 °C. If it is not inoculated and separated in time, it should be stored at -70°C or below.

 

Precautions:

 

① After the specimen is collected, the disposable sampling swab should be completely inserted into the preservation solution to maximize the retention of the specimen

 

② The collected specimens must be fresh and sent for inspection in time to avoid the death of pathogenic bacteria.

 

③ It is forbidden to use products with damaged packaging and expired expiry date to prevent pollution.

 

Note: This disposable sampler is used for in vitro diagnostic purposes, and cannot be used for internal or external use in humans or animals. If swallowed, it can cause serious incidents; it is irritating to eyes and skin. If splashed into eyes accidentally, rinse with water.

 

Precautions:

 

1. Clean before sampling.

 

2. When testing, you should stabilize your emotions, do not be overly nervous and shy, and do not cooperate with the doctor's work because of embarrassment, which will affect the sampling time of nucleic acid testing.

 

3. When using anal swabs to detect parasites, please do not take antiparasitic drugs.

 

4. People with hemorrhoids, perianal abscesses, anal erosions or ulcers are not suitable for anal swabs.

 

5. Those who have just completed hemorrhoids and anorectal surgery are not suitable for anal swabs.

 

6. Those who have the above situation should communicate with the sampling personnel in advance.

 

Packing specification:

 

25 servings/pack

500 servings/box

 

Model Number CY-90003Amies
Brand Name HUACHENYANG
Size /
Instrument Class I
Validity period 12 months
Place of Origin Guangdong, China

 

Expand more!
OEM ODM Fecal Collection Kit Anal Swab Stool Collection KitOEM ODM Fecal Collection Kit Anal Swab Stool Collection Kit

Click on the inquiry