Search productSearch post

Life technology is so close

Pharmaceutical Sciences

Disposable Anal Fecal Collection Kit Microbial Culture Swab Kit Single Use

Disposable Anal Fecal Collection Kit Microbial Culture Swab Kit Single Use

Product advantages:

 

With excellent sample collection and release capabilities, it can quickly adsorb small samples with high release efficiency. The duration of positive nucleic acid detection in anal swabs is longer than that in oral and pharyngeal swabs, which can supplement the detection loopholes of oral and pharyngeal swabs to prevent missed diagnosis. In the past oral and throat swab tests, samples were taken through the oral cavity or nasal cavity, which was an uncomfortable experience for the subjects. After sampling, some people would experience nausea, vomiting, nausea, etc., while The anal swab test will not have the above situation, but it will test the psychological endurance of the subjects. Anal swabs have a higher test duration and theoretically more accurately test samples

If you need free samples, you can submit an inquiry to us and we will reply immediately

*
*
*

Country

Submitting!
Successfully submitted!
Submission failed!
Email error!
Phone error!

Product Details:

Place of Origin: China
Brand Name: HUACHENYANG
Certification: ISO13485,NMPA,
Model Number: CY-930003T-Cary Blair

Disposable Anal Fecal Collection Kit Microbial Culture Swab Kit Single Use

Description

Model: CY-930003T-Cary Blair Brand: HUACHENYANG
Product Name: Sample Collection Kit Packaging Parameters 1: 25 Servings/pack
Packaging Parameters 2: 500 Servings/box Production Place: Shenzhen, China
High Light:

Anal Fecal Collection Kit

,

Disposable Fecal Collection Kit

,

Microbial fecal sample kit

 

Disposable Anal Fecal Collection Kit Microbial Culture Swab Kit Single Use

 

Disposable Sampler Stool Collection Kit Microbial Culture Swab Kit Anal Swab + Shipping Medium

 

Product advantages:

 

With excellent sample collection and release capabilities, it can quickly adsorb small samples with high release efficiency. The duration of positive nucleic acid detection in anal swabs is longer than that in oral and pharyngeal swabs, which can supplement the detection loopholes of oral and pharyngeal swabs to prevent missed diagnosis. In the past oral and throat swab tests, samples were taken through the oral cavity or nasal cavity, which was an uncomfortable experience for the subjects. After sampling, some people would experience nausea, vomiting, nausea, etc., while The anal swab test will not have the above situation, but it will test the psychological endurance of the subjects. Anal swabs have a higher test duration and theoretically more accurately test samples

 

Product Usage:

 

For sample collection, transportation and storage, etc.

 

Product parameter:

 

It consists of a swab and a test tube containing a preservation solution. Provided non-sterile.

 

model CY-930003T-Cary Blair
brand HUACHENYANG
product name Sample Collection Kit
Packaging parameters 1 25 servings/pack
Packaging parameters 2 500 servings/box
production place Shenzhen, China

 

Sample requirements:

 

The collected samples must be fresh and sent for inspection in time. The pathogenic bacteria after collection should be

It should be sent to the laboratory within 48 hours at 2-8 °C. If it cannot be sent to the laboratory within 48 hours, it should be stored at -70 °C or below. The pathogenic bacteria samples should be inoculated and separated as soon as possible after they are sent to the laboratory. After inoculation and separation within 48 hours, they can be stored at 2-8 °C. If it is not inoculated and separated in time, it should be stored at -70°C or below.

 

Precautions:

 

① After the specimen is collected, the disposable sampling swab should be completely inserted into the preservation solution to maximize the retention of the specimen

 

② The collected specimens must be fresh and sent for inspection in time to avoid the death of pathogenic bacteria.

 

③ It is forbidden to use products with damaged packaging and expired expiry date to prevent pollution.

 

Note: This disposable sampler is used for in vitro diagnostic purposes, and cannot be used for internal or external use in humans or animals. If swallowed, it can cause serious incidents; it is irritating to eyes and skin. If splashed into eyes accidentally, rinse with water.

 

FAQ:
Q1: Do you support OEM/ODM?
A: YES, we can prototype and customize the ideal product according to your specific application.
Q2: Do you have GMP Lab?
A: YES, we have our GMP Lab built in 2016.
Q3: Do you have any certificates?
A: YES, we have all the certificates required for export and local import custom clearance.
Q4: How long have you been in manufacturing medical consumables?
A: Established on 2008, our factory offer production, sales,delivery one-stop service.
Q5: Where is your main market located?
A: 60% in American Countries, 30% in European Countries and 10% in Middle East.
Expand more!
Disposable Anal Fecal Collection Kit Microbial Culture Swab Kit Single UseDisposable Anal Fecal Collection Kit Microbial Culture Swab Kit Single Use

Click on the inquiry