Life technology is so close
Pharmaceutical Sciences
Search productSearch post
Pharmaceutical Sciences
Product introduction:
The HUACHENYANG Transport System is the latest bacteriological transport swab that provides the ability and maintains the survival rate of discerning aerobic or anaerobic bacteria during collection, transport or indoor storage at the temperatures necessary for potassium chloride, magnesium chloride and calcium chloride ions, a suitable buffer can keep the sample morphology intact to the greatest extent, so that it can be fully suspended and dispersed. The specificity of using different reagent formulations and compatible swabs allows for larger sample collection, better transport and preservation.
If you need free samples, you can submit an inquiry to us and we will reply immediately
Product Details:
Place of Origin: | China |
---|---|
Brand Name: | HUACHENYANG |
Certification: | ISO13485,NMPA, |
Model Number: | CY-930003T-Cary Blair |
Description
Model: | CY-930003T-Cary Blair | Brand: | HUACHENYANG |
---|---|---|---|
Product Name: | Sample Collection Kit | Packaging Parameters 1: | 25 Servings/pack |
Packaging Parameters 2: | 500 Servings/box | Production Place: | Shenzhen, China |
High Light: |
Disposable Sampler Stool Collection Kit, sterile Stool Collection Kit, sterile stool sample collection kit |
Sterile Disposable Sampler Stool Collection Kit Microbial Culture Swab Kit
Disposable Sampler Stool Collection Kit Microbial Culture Swab Kit Anal Swab + Shipping Medium
Product introduction:
The HUACHENYANG Transport System is the latest bacteriological transport swab that provides the ability and maintains the survival rate of discerning aerobic or anaerobic bacteria during collection, transport or indoor storage at the temperatures necessary for potassium chloride, magnesium chloride and calcium chloride ions, a suitable buffer can keep the sample morphology intact to the greatest extent, so that it can be fully suspended and dispersed. The specificity of using different reagent formulations and compatible swabs allows for larger sample collection, better transport and preservation.
Product advantages:
With excellent sample collection and release capabilities, it can quickly adsorb small samples with high release efficiency. The duration of positive nucleic acid detection in anal swabs is longer than that in oral and pharyngeal swabs, which can supplement the detection loopholes of oral and pharyngeal swabs to prevent missed diagnosis. In the past oral and throat swab tests, samples were taken through the oral cavity or nasal cavity, which was an uncomfortable experience for the subjects. After sampling, some people would experience nausea, vomiting, nausea, etc., while The anal swab test will not have the above situation, but it will test the psychological endurance of the subjects. Anal swabs have a higher test duration and theoretically more accurately test samples
Product Usage:
For sample collection, transportation and storage, etc.
Product parameter:
It consists of a swab and a test tube containing a preservation solution. Provided non-sterile.
model | CY-930003T-Cary Blair |
brand | HUACHENYANG |
product name | Sample Collection Kit |
Packaging parameters 1 | 25 servings/pack |
Packaging parameters 2 | 500 servings/box |
production place | Shenzhen, China |
Product Instructions:
1. Take out the sampling swab, do not touch other parts or other places (so as not to contaminate the swab).
2. Gently insert the swab 3-5 cm into the anus.
3. Scrape a sufficient number of samples directly with a sampling rod, and the ratio of sample to preservation solution is 0.01-0.25:1.
4. Use the swab in the anus for 4~5 turns and then gently pull out the swab.
5. Put the sampling swab into the test tube containing the preservation solution, and quickly stir about 10 times to elute the sample on the swab. Then push the sampling swab head from the tail and tighten the cap
Sample requirements:
The collected samples must be fresh and sent for inspection in time. The pathogenic bacteria after collection should be
It should be sent to the laboratory within 48 hours at 2-8 °C. If it cannot be sent to the laboratory within 48 hours, it should be stored at -70 °C or below. The pathogenic bacteria samples should be inoculated and separated as soon as possible after they are sent to the laboratory. After inoculation and separation within 48 hours, they can be stored at 2-8 °C. If it is not inoculated and separated in time, it should be stored at -70°C or below.
Precautions:
① After the specimen is collected, the disposable sampling swab should be completely inserted into the preservation solution to maximize the retention of the specimen
② The collected specimens must be fresh and sent for inspection in time to avoid the death of pathogenic bacteria.
③ It is forbidden to use products with damaged packaging and expired expiry date to prevent pollution.
Note: This disposable sampler is used for in vitro diagnostic purposes, and cannot be used for internal or external use in humans or animals. If swallowed, it can cause serious incidents; it is irritating to eyes and skin. If splashed into eyes accidentally, rinse with water.